Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. J. Anesth. (Impr.) ; 73(6): 758-763, Nov.Dec. 2023. tab, graf
Article in English | LILACS | ID: biblio-1520378

ABSTRACT

Abstract Background: Reduced lumbar lordosis may make the process of identifying the intervertebral distance easier. The primary aim of this study was to measure the L3-L4 intervertebral space in the same patients undergoing spinal anesthesia in three different sitting positions, including the classic sitting position (CSP), hamstring stretch position (HSP) and rider sitting position (RSP). The secondary aim was to compare ultrasonographic measurements of the depth of the ligamentum flavum and intrathecal space in these three defined positions. Methods: This study is a single-blinded, prospective, randomized study. Ninety patients were included in final analysis. the patients were positioned on the operating table in three different positions to perform ultrasonographic measurements of the spinal canal. The intervertebral distance (IVD), the distance between the skin and the ligamentum flavum (DBSLF) and the intrathecal space (IS) were measured in the L3 -L4 intervertebral space in three different positions. Results: The RSP produced the largest mean distance between the spinous processes. The RSP yielded a significantly larger IVD than did the CSP (p < 0.001) and HSP (p < 0.001). The DBSP was larger in the CSP than in the HSP (p = 0.001). The DBSLF was significantly larger in the RSP than in the HSP (p = 0.009). Conclusions: Positioning the patient in the RSP significantly increased the intervertebral distance between L3 -L4 vertebrae compared to the CSP and HSP, suggesting easier performance of lumbar neuraxial block.


Subject(s)
Humans , Sitting Position , Anesthesia, Spinal , Prospective Studies , Lumbar Vertebrae/diagnostic imaging , Lumbosacral Region/diagnostic imaging
2.
Rev. bras. anestesiol ; 69(6): 553-560, nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057477

ABSTRACT

Abstract Background and objectives: The aim of this study was to investigate the efficacy of the pressure-controlled, volume-guaranteed (PCV-VG) and volume-controlled ventilation (VCV) modes for maintaining adequate airway pressures, lung compliance and oxygenation in obese patients undergoing laparoscopic hysterectomy in the Trendelenburg position. Methods: Patients (104) who underwent laparoscopic gynecologic surgery with a body mass index between 30 and 40 kg.m-2 were randomized to receive either VCV or PCV-VG ventilation. The tidal volume was set at 8 mL.kg-1, with an inspired oxygen concentration of 0.4 with a Positive End-Expiratory Pressure (PEEP) of 5 mmHg. The peak inspiratory pressure, mean inspiratory pressure, plateau pressure, driving pressure, dynamic compliance, respiratory rate, exhaled tidal volume, etCO2, arterial blood gas analysis, heart rate and mean arterial pressure at 5 minutes after induction of anesthesia in the and at 5, 30 and 60 minutes, respectively, after pneumoperitoneum in the Trendelenburg position were recorded. Results: The PCV-VG group had significantly decreased peak inspiratory pressure, mean inspiratory pressur, plateau pressure, driving pressure and increased dynamic compliance compared to the VCV group. Mean PaO2 levels were significantly higher in the PCV-VG group than in the VCV group at every time point after pneumoperitoneum in the Trendelenburg position. Conclusions: The PCV-VG mode of ventilation limited the peak inspiratory pressure, decreased the driving pressure and increased the dynamic compliance compared to VCV in obese patients undergoing laparoscopic hysterectomy. PCV-VG may be a preferable modality to prevent barotrauma during laparoscopic surgeries in obese patients.


Resumo Justificativa e objetivos: O objetivo deste estudo foi investigar a eficácia dos modos de ventilação garantida por volume controlado por pressão (PCV-VG) e ventilação controlada por volume (VCV) para manter pressões adequadas nas vias aéreas, complacência pulmonar e oxigenação em pacientes obesos submetidos à histerectomia laparoscópica na posição de Trendelenburg. Métodos: Cento e quatro pacientes submetidos à cirurgia ginecológica laparoscópica, com índice de massa corporal entre 30 e 40 kg.m-2, foram randomizados para receber ventilação com VCV ou PCV-VG. O volume corrente foi fixado em 8 mL.kg-1, com uma concentração inspirada de oxigênio de 0,4 e pressão positiva expiratória final (PEEP) de 5 mmHg. Registramos os seguintes parâmetros: pressão de pico inspiratório, pressão inspiratória média, pressão de platô, driving pressure, complacência dinâmica, frequência respiratória, volume corrente expirado, etCO2, gasometria arterial, frequência cardíaca e pressão arterial média aos 5, 30 e 60 minutos, respectivamente, após o pneumoperitônio na posição de Trendelenburg. Resultados: O grupo PCV-VG apresentou uma redução significativa da pressão de pico inspiratório, pressão inspiratória média, pressão de platô, driving pressure e aumento da complacência dinâmica comparado ao grupo VCV. Os níveis médios de PaO2 foram significativamente maiores no grupo PCV-VG do que no grupo VCV em todos os momentos após o pneumoperitônio na posição de Trendelenburg. Conclusões: O modo de ventilação PCV-VG limitou a pressão de pico inspiratório, diminuiu a driving pressure e aumentou a complacência dinâmica, comparado ao VCV em pacientes obesas submetidas à histerectomia laparoscópica. O PCV-VG pode ser uma modalidade preferida para prevenir o barotrauma durante cirurgias laparoscópicas em pacientes obesos.


Subject(s)
Humans , Female , Adult , Gynecologic Surgical Procedures/methods , Laparoscopy/methods , Head-Down Tilt , Obesity/complications , Oxygen/metabolism , Respiration, Artificial/methods , Tidal Volume/physiology , Lung Compliance/physiology , Prospective Studies , Positive-Pressure Respiration , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL